What is Powercode
Power Cords Are Essential For Connecting Devices To Electrical Outlets
A power cord, line cord, or mains cable is an electrical cable that temporarily connects an appliance to the mains electricity supply via a wall socket or extension cord. The terms are generally used for cables using a power plug to connect to a single-phase alternating current power source at the local line voltage (generally 100 to 240 volts, depending on the location). The terms power cable, mains lead, flex or kettle lead are also used. A lamp cord (also known as a zip cord) is a light-weight, ungrounded, single-insulated two-wire cord used for small loads such as a table or floor lamp.
2 Pin Class-II - 2.5 AMP Indian Plug
- The Type C electrical plug (or Indian plug) is a two wire plug that has two round pins.
- It fits into any socket that accepts 5.03 – 5.105 mm round contacts on 16.30 mm centers.
- They are being replaced by E, F, J, K or N sockets, Which work perfectly with type C plugs.
- Type C plug are generally limited for use in appliance that require 2.5 AMP or less.
Technical Specifications
| Cable | Description | Model No. | Standard | Rating |
|---|---|---|---|---|
| 0.50 SQ MM X 2C (FLAT) | 2 PIN INDIAN PLUG | Type C | As Per IS : 1293 | 2.5 A 250 V |
| 0.75 SQ MM X 2C (FLAT) | 2 PIN INDIAN PLUG | Type C | As Per IS : 1293 | 2.5 A 250 V |
The available cable IS 694 ; 2010, IEC 60227
- The plug is rated for a maximum current of 2.5 amperes. This determines the maximum electrical load that the plug can safely handle.
- These plugs are usually made of high-quality, durable materials that are resistant to wear and tear, ensuring a longer lifespan.
- The plug is designed for easy insertion and removal from electrical outlets, providing a convenient and hassle-free user experience.
- The “Class-II” designation means that the plug is double-insulated. This provides an extra layer of safety against electric shocks, making it safer to use.
- These plugs are usually made of high-quality, durable materials that are resistant to wear and tear, ensuring a longer lifespan.
2 Pin Class-II 6/10 AMP Indian Plug
The Type C electrical plug is two wire plugs that have two round pins.
It fits into any socket that accepts 5.03 – 5.105 mm round contacts on 16.30 mm centers.
They are being replaced by E, F, J, K or N sockets, Which work perfectly with type C plugs.
They are being replaced by E, F, J, K or N sockets which work perfectly with Type C plugs.
Technical Specifications
| Cable | Description | Model No. | Standard | Rating |
|---|---|---|---|---|
| 0.50 SQ MM X 2C | 2 PIN STRAIGHT PLUG | Type C | As Per IS : 1293 | 6 A 250 V |
| 0.75 SQ MM X 2C | 2 PIN STRAIGHT PLUG | Type C | As Per IS : 1293 | 6 A 250 V |
| 1.00 SQ MM X 2C | 2 PIN STRAIGHT PLUG | Type C | As Per IS : 1293 | 10 A 250 V |
| 1.50 SQ MM X 2C | 2 PIN STRAIGHT PLUG | Type C | As Per IS : 1293 | 10 A 250 V |
The available cable IS 694 ; 2010, IEC 60227
- Require only two connections – typically small electronic devices or appliances with lower power requirements.
- Class-II plugs are double-insulated, meaning they have extra layers of insulation to provide additional protection against electric shocks. This is especially important for smaller appliances that might not have an earth connection.
- It can handle a maximum current of either 6 or 10 amperes, depending on the specific variant. This rating determines the maximum amount of electrical current the plug can safely carry without overheating or causing damage.
3 Pin Class-I 6/10 AMP Indian Plug
- The Type D electrical plug has three round pin in a triangular pattern.
- Type M plug are often used alongside Type D plugs for large appliance and as a result, some socket work both Type D and Type M plugs.
Technical Specifications
| Cable | Description | Model No. | Standard | Rating |
|---|---|---|---|---|
| 0.50 SQ MM X 2C | 3 PIN STRAIGHT PLUG | Type D | As Per IS : 1293 | 6-10 A 250 V |
| 0.75 SQ MM X 2C | 3 PIN STRAIGHT PLUG | Type D | As Per IS : 1293 | 6-10 A 250 V |
| 1.00 SQ MM X 2C | 3 PIN STRAIGHT PLUG | Type D | As Per IS : 1293 | 6-10 A 250 V |
| 1.50 SQ MM X 2C | 3 PIN STRAIGHT PLUG | Type D | As Per IS : 1293 | 6-10 A 250 V |
The available cable IS 694 ; 2010, IEC 60227
- One of these pins is the earth pin, which provides an additional safety feature by grounding the appliance, reducing the risk of electric shock.
- Class-I plugs are designed with an earth pin for grounding, providing an extra layer of safety compared to Class-II plugs, which rely solely on insulation for protection against electric shocks.
- Similar to the 2-pin plug, this indicates the current rating of the plug. It can handle a maximum current of either 6 or 10 amperes, depending on the specific variant. This rating determines the maximum amount of electrical current the plug can safely carry without overheating or causing damage.
- In addition to the earth connection, Class-I plugs may include features such as built-in fuses or surge protection to further enhance safety.
3 Pin Class-I 10/16 AMP Indian Plug
- The Type D electrical plug has three round pin in a triangular pattern.
- Type M plug are often used alongside Type D plugs for large appliance and as a result, some socket work both Type D and Type M plugs.
Technical Specifications
| Cable | Description | Model No. | Standard | Rating |
|---|---|---|---|---|
| 0.50 SQ MM X 2C | 3 PIN STRAIGHT PLUG | Type D | As Per IS : 1293 | 10-16 A 250 V |
| 0.75 SQ MM X 2C | 3 PIN STRAIGHT PLUG | Type D | As Per IS : 1293 | 10-16 A 250 V |
| 1.00 SQ MM X 2C | 3 PIN STRAIGHT PLUG | Type D | As Per IS : 1293 | 10-16 A 250 V |
| 1.50 SQ MM X 2C | 3 PIN STRAIGHT PLUG | Type D | As Per IS : 1293 | 10-16 A 250 V |
The available cable IS 694 ; 2010, IEC 60227
- The plug consists of three pins, including one earth pin, designed to be compatible with Indian electrical outlets. The earth pin provides grounding for enhanced safety.
- The plug includes an earth connection, which is essential for grounding the connected device and reducing the risk of electric shock. Class-I plugs offer superior safety compared to Class-II plugs, as they provide both insulation and grounding.
- This plug variant is available with two different current ratings: 10 amperes and 16 amperes. The rating determines the maximum electrical current that the plug can safely handle. The 10/16 AMP plug is suitable for devices with higher power requirements, such as large appliances or equipment.
- In addition to the earth connection, Class-I plugs may incorporate additional safety features such as thermal overload protection or surge protection to safeguard connected devices from electrical surges and fluctuations.
- Due to its 10/16 AMP rating, this plug is suitable for use with high-power electrical appliances and equipment, including air conditioners, refrigerators, washing machines, and industrial machinery.
3 Pin 13 AMP British Plug
The Type G electrical plug has three rectangular blades in a triangular pattern and has an incorporated fuse (usually a 3 amps fuse for smaller appliance such as a computer and a 13 amps one for heavy duty appliance such as HEATER, MIXER, AIR COOLER.ETC ).
Technical Specifications
| Cable | Description | Model No. | Standard | Rating |
|---|---|---|---|---|
| 0.75 SQ MM X 3C | 3 PIN BRITISH PLUG | TYPE G | As Per BS : 1363 | 5A/250 V |
| 1.00 SQ MM X 3C | 3 PIN BRITISH PLUG | TYPE G | As Per BS : 1363 | 10A/250 V |
| 1.50 SQ MM X 3C | 3 PIN BRITISH PLUG | TYPE G | As Per BS : 1363 | 13A/250 V |
Note :The above specification cables used for IEC60227
- The plug is rated to handle a maximum current of 13 amperes. This rating indicates the maximum electrical load that the plug can safely carry without overheating or causing damage.
- Most British plugs are equipped with a fuse, usually located in the live pin. The fuse protects the connected appliance or device from electrical overload by breaking the circuit if the current exceeds a safe level.
- The plug conforms to British Standard BS 1363, ensuring compatibility with UK electrical outlets and compliance with safety regulations. This standard specifies the dimensions, configuration, and safety requirements for plugs and sockets used in the UK.
- Many UK plugs feature built-in safety shutters over the live and neutral pins. These shutters prevent accidental insertion of foreign objects into the socket, reducing the risk of electric shock.
- The plug typically includes markings or indicators to denote the correct orientation for insertion into the socket. This ensures proper alignment of the live, neutral, and earth connections.
- The earth pin provides grounding for connected devices, reducing the risk of electric shock and providing protection against electrical faults.
Technical Specifications
| Nominal Area of Conductor | Number/Nom. Dia. of Wires (Nom) | Thickness of Insulation | Overall Diameter Max. | Current Rating | Resistance (Max.) D.C. at 20 C |
|---|---|---|---|---|---|
| Sq. mm | No. / mm | No. / mm | mm | Amps. | Ohms / Km |
| 0.75 | 24/0.20* | 0.6 | 2.50 | 7 | 26.00 |
| 0.75 | 24/0.20* | 0.6 | 2.50 | 7 | 26.00 |
| 0.75 | 24/0.20* | 0.6 | 2.50 | 7 | 26.00 |
| 0.75 | 24/0.20* | 0.6 | 2.50 | 7 | 26.00 |
| 0.75 | 24/0.20* | 0.6 | 2.50 | 7 | 26.00 |
| 0.75 | 24/0.20* | 0.6 | 2.50 | 7 | 26.00 |
In view of continuous improvements in our design and process, specifications given here in are subject change without notice.